| Wisconsin. State Board of Health - Plumbing - 1916 - 156 pages
...pipe, or lead, brass or copper. (b) Minimum Size of Vent Stack. Where not more than two water closets are installed below the first floor and serve as the...bath, one basin, one sink or other similar fixture. The size of the vent and waste pipes for basins, sinks, baths, or other similar fixtures when they... | |
| 1917 - 370 pages
...open trench work. Section 5. (b) Minimum Size of Vent Htatk. Where not more than two water closets are installed below the first floor and serve as the...the building the vent pipe shall not be less than 2 inches. In determining the size of the vent pipe allow in addition to the closet, one bath, one basin,... | |
| Wisconsin. State Board of Health - Public health - 1917 - 344 pages
...open trench work. Section 5. (b) Minimum Size of Vent Stack. Where not more than two water closets are installed below the first floor and serve as the...the building the vent pipe shall not be less than 2 inches. In determining the size of the vent pipe allow in addition to the closet, one bath, one basin,... | |
| George A. Hool, Nathan Clarke Johnson - Building - 1920 - 684 pages
...coated with tar or aaphaltum, galvanized wrought iron or steel pipe, or lead, brass or copper. (6) Minimum Size of Vent Stack. — W-here not more than...as the only closets in the building, the vent pipe should not be less than 2 in. In determining the size of the D Chart showing maximum developed drskmcf... | |
| George A. Hool, Nathan C. Johnson - Building - 1920 - 676 pages
...coated with tar or asphaltum, galvanized wrought iron or steel pipe, or lead, brass or copper. (6) Minimum Size, of Vent Stack. — Where not more than...water-closets are installed below the first floor mnd serve as the only closets in the building, the vent pipe should not be less than 2 in. In determining... | |
| George A. Hool, Nathan C. Johnson - Building - 1920 - 684 pages
...coated with tar or asphaltum, galvanized wrought iron or steel pipe, or lead, brass or copper. (6) Minimum Size of Vent Stack. — Where not more than two water-closets are installed below the first 8oor and serve as the only closets in the building, the vent pipe should not be less than 2 in. In... | |
| Wisconsin. State Board of Health - Plumbing - 1922 - 212 pages
...against the corrosive action of such concrete by thoroughly applying one or more than two water-closets paint or adequate tar paper wrapping or both, or by...installed below the first floor and serve as the only 1 3 or mart i closets in the building, the Sketch No. 8. — Illustrating min- . imum requirements... | |
| |